R32 — 1HP
RM 130 · ~600g charge.
If your aircon needs gas after three years, something on the line let it out. Could be a slow flare-nut weep, a Schrader valve, or a coil pinhole. Whatever the cause, just topping up gives you another six months of cooling before the same problem reappears — at full cost.
Our standard process is: bring the manifold gauges, check static and operating pressures, soap-test all visible joints, and only then quote a refill. If we find a leak, we quote the leak repair first. It's not the easy upsell — but it's the honest one.
Static then operating. Low-side and high-side noted. Brand & refrigerant type confirmed.
Soap-test of flare nuts, valve cores, Schrader caps, accessible piping joints. Optional UV trace dye on chronic leaks.
If a leak is found, leak repair is quoted before refill. If clean, refill is quoted with refrigerant type confirmed.
Charged by weight on a digital scale to the nameplate spec — not "until it feels right".
Run unit 20 minutes, log supply-air °C, refrigerant weight added, job sheet emailed within 24 hours.
RM 130 · ~600g charge.
RM 200 · ~1.0kg charge.
RM 180
RM 280
RM 240 · subject to availability; we'll advise on retrofit options.
Free when bundled with any service. RM 80 stand-alone (waived if you proceed).
Honest refrigerant work, weighed in not eyeballed in, properly invoiced — and a fix that doesn't come back next quarter.